For full functionality of this site it is necessary to enable JavaScript. Here are the instructions how to enable JavaScript in your web browser.

Minimum cover: the reduction Δcdur,add for concrete with additional protection

Eurocode 2 part 1-1: Design of concrete structures   4.4.1.2 (8)

For concrete with additional protection (e.g. coating) the minimum cover may be reduced by Δcdur,add.

Recommendation

The recommended value for Δcdur,add, without further specification, is 0 mm.

National choice

Δcdur,add
...
[mm]
...