For full functionality of this site it is necessary to enable JavaScript. Here are the instructions how to enable JavaScript in your web browser.

Columns: the maximum spacing of transverse reinforcement scl,tmax

Eurocode 2 part 1-1: Design of concrete structures   9.5.3 (3)

Recommendation

The recommended value for the maximum spacing of transverse reinforcement along the column scl,tmax is the least of the three distances:

  • 20 times the minimum diameter of the longitudinal bars
  • the lesser dimension of the column
  • 400 mm.

National choice

scl,tmax
...
[mm]
...