Members requiring design vertical shear reinforcement: the guidance on the superposition of different truss models

Eurocode 2 part 2: Design of concrete bridge structures   6.2.3 (107)

Recommendation

In the case of bonded prestressing, located within the tensile chord, the resisting effect of prestressing may be taken into account for carrying the total longitudinal tensile force. In the case of inclined bonded prestressing tendons in combination with other longitudinal reinforcement/tendons the shear strength may be evaluated, by a simplification, superimposing two different truss models with different geometry (Figure 6.102N); a weighted mean value between θ1 and θ2 may be used for concrete stress field verification with Expression (6.9).

National choice

the guidance on the superposition of different truss models
...
...