Columns: the minimum area of longitudinal reinforcement As,min
Eurocode 2 part 1-1: Design of concrete structures 9.5.2 (2)
Recommendation
The recommended value for the minimum area reinforcement As,min is:
As,min = (0,10 NEd)/fyd ≥ 0,002 Ac | (9.12N) |