For full functionality of this site it is necessary to enable JavaScript. Here are the instructions how to enable JavaScript in your web browser.

Anchorages and couplers for prestressing tendons: the value of X % and the distance a

Eurocode 2 part 2: Design of concrete bridge structures   8.10.4 (105)

The placing of couplers on more than X % of the tendons at one cross-section should be avoided (unless specific conditions are satisfied).

Where a proportion of tendons are joined with couplers at a particular cross section, remaining tendons may not be joined with couplers within distance a of the that cross section.

Recommendation

The recommended value for X is 50 %. The recommended value for the maximum percentage of tendons to be coupled at a section is 67 %. The recommended value for the distance a is given in Table 8.101N.

National choice

...
The percentage of tendons
The distance
X
...