Deep beams: the maximum spacing of adjacent bars smesh
Eurocode 2 part 2: Design of concrete bridge structures 9.7 (102)
Recommendation
The recommended value for the maximum spacing of adjacent bars smesh is the lesser of the web thickness or 300 mm.